VAV, FPU Properties

Property Name Description
Body | Depth Positive <numeric value>
  • Sets the depth of entire unit.
Body | Length Positive <numeric value>
  • Sets overall length.
Body | Width Positive <numeric value>
  • Sets the width of entire unit.
Cell Library <cell library file name>
  • Library file name for device cells.
Cell Symbol Name <cell name>
  • Sets the model cell to the device.
Prerequisite of proper Cell Library for AHUs.
Coil | Offset Positive <numeric value>
  • Sets distance between the two coil connections. Limited by device body dimension properties.
Coil Connection | Side
  • 1-back
  • 2-front
  • 3-top
  • 4-bottom
  • Sets the location or surface on the unit for coil connections.
Coil Connection | Outer Diameter Positive <numeric value>
  • Sets outside diameter of coil connections.
Coil Connection | Offset Positive <numeric value>
  • Sets an offset distance between coil connections and back of device.
Coil | Type
  • 0-none
  • 1-plumbing
  • 2-electrical
  • Sets the type of heating coil.

    Type plumbing adds provision for inlet/outlet of pipes.
Connection 1 | Length (L1) Positive <numeric value>
  • Sets straight length at End1.
  • Sets connection length at End1.
Connection 2 | Length (L2) Positive <numeric value>
  • Sets straight length at End2.
  • Sets connection length at End2.
Connection 3 | Length (L3) Positive <numeric value>
  • Sets straight length at End3.

Adds to the Body Length property.

Connection | End Type fl -<numeric value>
  • Sets and sizes end with a flange connection.
m -<numeric value>
  • Sets and sizes end with a male connection.
fe -<numeric value>
  • Sets and sizes end with a female connection.
Separate End Type entries for each End Spec with a semi colon.

Example: fl-2;fe-.13 creates a flange at End1 with size 2, and a female connection at End2 with an overall reduction of component's dimensions of .13

Control | Connection Side
  • 1-back
  • 2-front
  • 3-top
  • 4-bottom
  • Sets the location or surface on which the device control box is located.
Control | Depth Positive <numeric value>
  • Sets the depth of the control box mounted on the unit.
Control1 | Depth Positive <numeric value>
  • Sets the depth of the first control box mounted on a dual inlet device.
Control2 | Depth Positive <numeric value>
  • Sets the depth of the second control box mounted on a dual inlet device.

Control | Length Positive <numeric value>
  • Sets the length of the control box mounted on the unit.
Control1 | Length Positive <numeric value>
  • Sets the length of the first control box mounted on a dual inlet device.
Control2 | Length Positive <numeric value>
  • Sets the length of the second control box mounted on a dual inlet device.
Control | Offset <numeric value>
  • Sets an offset distance between the front surfaces of the control box and the device body.
Control1 Offset <numeric value>
  • Sets an offset distance between the front surfaces of the first control box and the device body.
Control2 | Offset <numeric value>
  • Sets an offset distance between the front surfaces of the second control box and the device body.
Control | Side Distance Positive <numeric value>
  • Sets the offset distance between the bottom of the control box and the bottom of the device on which it is mounted.
Control | Width Positive <numeric value>
  • Sets the width of the control box mounted on the unit.
Control1 Width Positive <numeric value>
  • Sets the width of the first control box mounted on a dual inlet device.
Control2 Width Positive <numeric value>
  • Sets the width of the second control box mounted on a dual inlet device.
Electrical Extension Positive <numeric value>
  • Sets length of electrical connection box.
    Note: Coil Type property must be set to <2–electrical>.
Induction Bottom Distance Positive <numeric value>
  • Sets offset distance between the bottom of induction opening and the bottom of device box. Limited by body dimensional properties.
Induction Depth Positive <numeric value>
  • Sets induction opening depth. Limited by body dimensional properties.
Induction Length Positive <numeric value>
  • Sets induction opening length.
Induction Side Distance Positive <numeric value>
  • Sets offset distance between the side of induction opening and the side of device box. Limited by body dimensional properties.
Induction Width Positive <numeric value>
  • Sets induction opening width. Limited by body dimensional properties.
Inlet | Bottom Distance Positive <numeric value>
  • Sets offset distance between the bottom of End1 and the bottom of device box. Limited by body dimensional properties.
Inlet | Offset Positive <numeric value>
  • Sets offset distance between the inlets on a dual inlet device.
Limited by the sum of the inlet radii and the size of the device enclosure.
Inlet | Side Distance Positive <numeric value>
  • Sets offset distance between the side of End1 and the side of device box. Limited by body dimensional properties.
Outlet Bottom Distance Positive <numeric value>
  • Sets offset distance between the bottom of End2 and the bottom of device box. Limited by body dimensional properties.
Outlet | Side Distance Positive <numeric value>
  • Sets offset distance between the side of End2 and the side of device box. Limited by body dimensional properties.
Replaced Cell Tag <tag>;<tag>;<tag>;<tag>
  • Sets tags displayed in drawing output.
This property is set to un-editable by default.
Side Distance Positive <numeric value>
  • Sets the offset distance between the device enclosure's front side and the center line of the first inlet (End1).
Tag <alpha-numeric characters>
  • Sets tag value visible in output of drawing composition in dynamic view. Separate tag strings with a semi colon
VAV Box Type
  • 1-leftHanded
  • 2-rightHanded
  • Sets the side of the control box on the unit.
By default, set hidden by in catalog Editor.

Modifying this property maintains the location of the inlets.

Property Option menus are available to assist in making some property entries.